Search results for "Arterial occlusion"
showing 10 items of 19 documents
Optical noninvasive monitoring of skin blood pulsations
2005
Time-resolved detection and analysis of skin backscattered optical signals (remission photoplethysmography or PPG) provide rich information on skin blood volume pulsations and can serve for reliable cardiovascular assessment. Single- and multiple-channel PPG concepts are discussed. Simultaneous data flow from several locations on the human body allows us to study heartbeat pulse-wave propagation in real time and to evaluate vascular resistance. Portable single-, dual-, and four-channel PPG monitoring devices with special software have been designed for real-time data acquisition and processing. The prototype devices have been clinically studied, and their potential for monitoring heart arrh…
Two-stage multi-Gaussian fitting of conduit artery photoplethysmography waveform during induced unilateral hemodynamic events.
2014
Photoplethysmography (PPG) is an optical technique with high diagnostic potential, yet clinical applications remain underdeveloped. Standardization of signal recording and quantification of waveform are essential prerequisites for broader clinical use. The aim of this study was to utilize a two-stage multi-Gaussian fitting technique in order to examine the parameters of conduit artery PPG waveform recorded during increasing the unilateral regional vascular resistance (RVR). This study was conducted on 14 young and healthy volunteers; various external compressions (ECs) were performed by inflating a tight cuff at 0, 40, 80, and 200 mmHg, while registering femoral PPG (wavelength 880 nm), dia…
How to Handle Arterial Conduits in Liver Transplantation? Evidence From the First Multicenter Risk Analysis
2020
OBJECTIVE: The aims of the present study were to identify independent risk factors for conduit occlusion, compare outcomes of different AC placement sites, and investigate whether postoperative platelet antiaggregation is protective. BACKGROUND: Arterial conduits (AC) in liver transplantation (LT) offer an effective rescue option when regular arterial graft revascularization is not feasible. However, the role of the conduit placement site and postoperative antiaggregation is insufficiently answered in the literature. STUDY DESIGN: This is an international, multicenter cohort study of adult deceased donor LT requiring AC. The study included 14 LT centers and covered the period from January 2…
Imaging photoplethysmography for clinical assessment of cutaneous microcirculation at two different depths
2016
The feasibility of bispectral imaging photoplethysmography (iPPG) system for clinical assessment of cutaneous microcirculation at two different depths is proposed. The iPPG system has been developed and evaluated for in vivo conditions during various tests: (1) topical application of vasodilatory liniment on the skin, (2) skin local heating, (3) arterial occlusion, and (4) regional anesthesia. The device has been validated by the measurements of a laser Doppler imager (LDI) as a reference. The hardware comprises four bispectral light sources (530 and 810 nm) for uniform illumination of skin, video camera, and the control unit for triggering of the system. The PPG signals were calculated and…
Incidence of Acute Ischemic Stroke With Visible Arterial Occlusion
2020
Background and Purpose: Because of several methodological limitations, previous studies focusing on the prevalence of large vessel occlusion in ischemic stroke (IS) patients provided conflicting results. We evaluated the incidence of IS with a visible arterial occlusion using a comprehensive population-based registry. Methods: Patients with acute IS were prospectively identified among residents of Dijon, France, using a population-based registry (2013–2017). All arterial imaging exams were reviewed to assess arterial occlusion. Annual incidence rates of IS (first-ever and recurrent events) and IS with a visible occlusion were calculated. Results: One thousand sixty cases of IS were recorde…
Response by Béjot and Duloquin to Letter Regarding Article, "Incidence of Acute Ischemic Stroke With Visible Arterial Occlusion: A Population-Based S…
2020
LASCA and PPG imaging for non-contact assessment of skin blood supply
2013
Laser speckle contrast analysis (LASCA) offers a non-contact, full-field, and real-time mapping of capillary blood flow and can be considered as an alternative method to Laser Doppler perfusion imaging (LDPI). Photoplethysmography (PPG) is well known technique for assessment of skin blood pulsations that can be related to blood flow. In recent years several studies have been done on development of non-contact PPG imaging (PPGI). LASCA and PPGI techniques are simpler and cheaper compared with LDPI. LASCA technique has been implemented in several commercial instruments. However, these systems are still too expensive and bulky to be widely available. Several optical techniques have found new i…
Optical systems for non-invasive cardiovascular biosensing
2005
Three portable prototype devices for cardiovascular biosensing based on reflection-type photoplethysmography (PPG) principle have been designed and clinically tested. The single-channel PPG finger sensor provides real-time measurements with fast calculation of the mean single-period PPG signal shape ("cardiovascular fingerprint", potentially useful for recognition). The dual-channel PPG system gives additional possibility to monitor on-line the arterial pulse wave transit time and its responses to physical exercises. The four-channel PPG system proved to be applicable for fast detection of cardiovascular pathologies, e.g. arterial occlusions in extremities. Design principles and software al…
Optical multichannel sensing of skin blood pulsations
2004
Time resolved detection and analysis of the skin back-scattered optical signals (reflection photoplethysmography or PPG) provide information on skin blood volume pulsations and can serve for cardiovascular assessment. The multi-channel PPG concept has been developed and clinically verified in this study. Portable two- and four-channel PPG monitoring devices have been designed for real-time data acquisition and processing. The multi-channel devices were successfully applied for cardiovascular fitness tests and for early detection of arterial occlusions in extremities. The optically measured heartbeat pulse wave propagation made possible to estimate relative arterial resistances for numerous …
<title>Optical non-invasive monitoring of skin blood pulsations</title>
2005
Time resolved detection and analysis of the skin backscattered optical signals (remission photoplethysmography or PPG) provide rich information on skin blood volume pulsations and can serve for reliable cardiovascular assessment. The single- and multi-channel PPG concepts are discussed in this work. Simultaneous data flow from several body locations allows one to study the heartbeat pulse wave propagation in real time and evaluate the vascular resistance. Portable single-, dual- and four-channel PPG monitoring devices with special software have been designed for real-time data acquisition and processing. The clinical studies confirmed their potential in the monitoring of heart arrhythmias, …